PIGMENT™ | Q-SWITCHED ND:YAG
Tattoo Removal, Pigment & Skin Rejuvenation Laser for professional
PIGMENT™ delivers high-peak, ultra-short nanosecond pulses that target unwanted ink and pigment with precision — fragmenting the target while preserving the surrounding skin. One platform, four treatments, one investment.
Scientific diagnostic for skin & hair analysis
Dual Wavelength
532 & 1064nm
Up to 800 mJ
High peak energy
≤ 6 nanosecond
Ultra-short pulse
532 nm wavelength
- Removal of light-ink tattoos — red, sky blue, green, purple, and orange
- Benign vascular lesions, including but not limited to telangiectasias (small surface vessels / "spider veins")
- Benign epidermal pigmented lesions, including but not limited to café-au-lait, solar lentigines, senile lentigines, Becker's nevi, freckles, nevus spilus, and seborrheic keratoses
- Post-inflammatory hyperpigmentation
1064 nm wavelength
- Removal of dark-ink tattoos — black, blue, and brown
- Benign dermal pigmented lesions, including but not limited to Nevus of Ota, common nevi, and melasma
- Removal or lightening of unwanted hair, with or without adjuvant preparation
- Skin resurfacing for the treatment of acne scars and wrinkles
How does it work?
PIGMENT™ is built around a simple physical principle: deliver energy that the target absorbs strongly and the surrounding skin largely ignores. The laser emits ultra-short, high-peak pulses tuned to wavelengths that ink and pigment absorb far more readily than healthy tissue. Because each pulse lasts only nanoseconds, the energy arrives faster than heat can spread to neighbouring cells — so the target takes the full impact while the skin around it is spared.
When a pulse strikes concentrated pigment, that sudden burst creates a rapid photoacoustic (pressure) effect that fractures the particle into microscopic fragments. The fragments are small enough for the body's own immune system to carry away over the following weeks — which is why results build gradually across a course of sessions rather than appearing all at once.
A flat-top beam profile spreads each pulse evenly across the spot rather than peaking in the centre, helping deliver uniform, predictable energy across the treatment area.
____
Matching the mechanism to the treatment
- For tattoo removal, repeated sessions progressively fragment and fade unwanted ink, with the wavelength chosen to suit the ink colour.
- For benign pigmented lesions, the same selective absorption breaks up excess melanin so the mark lightens.
- For benign vascular lesions, energy is absorbed within the targeted surface vessels.
- For unwanted hair, 1064 nm energy is absorbed along the follicle to reduce regrowth.
- For acne scars and wrinkles, controlled energy supports skin-resurfacing.
Throughout, the goal is the same: deliver precisely enough energy to act on the target while helping preserve the surrounding skin.
Two Working Modes
Q-Switched High-peak, ultra-short pulses interact with unwanted pigment to support effective tattoo and pigment-focused treatments.
SPT (Long Pulse) Gradual energy delivery provides smooth, controlled skin-toning and overall skin-quality enhancement.
In Q-Switched mode, all the energy is dumped in roughly 6 nanoseconds. Cramming energy into such a tiny window produces an enormous peak power — the tall spike. That sudden, violent burst creates a photoacoustic (pressure) effect that physically shatters tattoo ink and pigment into tiny fragments the body clears away. The total energy is modest, but the intensity per instant is huge.
In SPT (long-pulse) mode, the same kind of energy is released gradually over about 300 microseconds — roughly 50,000 times longer. Spread out like that, the peak power is far lower (the short, wide block), so instead of shattering anything it gently heats the tissue. That controlled warming is what stimulates collagen and is used for skin toning and rejuvenation.
Optional Handles
585 NM DYE HP
Size: Ø 31.5 × 186mm
Parameters: input 532nm, output 585nm
Conversion efficiency: 60-70%
Spot size: input 12-15mm, output 2-3mm
Lifetime: 20000 times
Special attention:
The input spot must be 532nm
Spot energy density ≤ 0.5J/cm2
Pulse width: 8-10ns
Working frequency: 1-2Hz
650 NM DYE HP
Size: Ø 31.5 × 186mm
Parameters: input 532nm, output 650nm
Conversion efficiency: 40-50%
Spot size: input 12-15mm, output 2-3mm
Lifetime: 20000 times
Special attention:
The input spot must be 532nm
Spot energy density ≤ 0.5J/cm2
Pulse width: 8-10ns
Working frequency: 1-2Hz
1064 DOE HP
Size: Ø31.5 × 176.5mm
Working wavelength: 532nm or 1064nm (for single wavelength use)
Maximum input spot size: Ø 12mm
Output spot size: 10 × 10mm (square)
FLA HP
Size: Ø31.5 × 176.5mm
Maximum input spot size: Ø 12mm
Point size: approximately Ø 0.5mm
The output spot shape is circular
-
Operating Modes
Q-Switched & SPT (Long Pulse)
-
Beam Profile
Flat-top
-
Wavelengths
1064 nm / 532 nm
-
Pulse Energy (1064 nm, Q-Switched)
100–800 mJ single pulse · up to 1200 mJ double pulse
-
Pulse Energy (532 nm, Q-Switched)
50–320 mJ single pulse · up to 480 mJ double pulse
-
Pulse Width
≤ 6 ns (Q-Switched) · 300 µs (SPT)
-
Spot Size
2–10 mm
-
Repetition Rate
Max 10 Hz (1064 nm, 532 nm, SPT)
-
Optical Delivery
Articulated arm (imported from South Korea)
-
Aiming Beam
655 nm red diode, adjustable brightness
-
Energy Calibration
External & self-calibration
-
Cooling
Air + water + semiconductor cooling
-
Interface
12″ true-color touchscreen
-
Power Supply
AC 110 V or 230 V, 50/60 Hz
The Corpoderm package includes:
Training
PIGment comes with a complementary 2-day training to cover in-depth the theory of this technology as well as the practice side of things, including safety guidelines.
Delivery
Like everything other Corpoderm devices, PIGMent's delivery is included in your price.
Warranty
Corpoderm praises itself in providing state-of-the-art services. With PIGMent comes a 2-year limited warranty, bringing you peace of mind.
English (United States)